Furnace Gas Line Drip Leg

Mid Efficiency Gas Furnace Diagram Gas Furnace Refrigeration And Air Conditioning Home Furnace

Mid Efficiency Gas Furnace Diagram Gas Furnace Refrigeration And Air Conditioning Home Furnace

Pvc Drip Leg Hvac Hacks Com Hvac Hacks Hvac Humor Hvac

Pvc Drip Leg Hvac Hacks Com Hvac Hacks Hvac Humor Hvac

Conventional Gas Furnace Gas Furnace Refrigeration And Air Conditioning Home Furnace

Conventional Gas Furnace Gas Furnace Refrigeration And Air Conditioning Home Furnace

Gas Furnace Nightmare Hvac Hacks Com Gas Furnace Hvac Hacks Furnace

Gas Furnace Nightmare Hvac Hacks Com Gas Furnace Hvac Hacks Furnace

Pin On Tempboard3

Pin On Tempboard3

Are You Thinking Of Becoming A Home Inspector If This Looks Foreign To You We Can Help Our Home I High Efficiency Gas Furnace Home Inspector Home Inspection

Are You Thinking Of Becoming A Home Inspector If This Looks Foreign To You We Can Help Our Home I High Efficiency Gas Furnace Home Inspector Home Inspection

Are You Thinking Of Becoming A Home Inspector If This Looks Foreign To You We Can Help Our Home I High Efficiency Gas Furnace Home Inspector Home Inspection

Sediment traps are usually installed very close to the water heater or furnace valve.

Furnace gas line drip leg.

Drip legs or sediment traps the technical term are supposed to be installed as close as possible to the inlet of every appliance as required. The drip leg sediment trap called by either name is a gas line safety device required by the national fuel gas code ansi z223 1 nfpa 54 and by the irc international residential code the upc uniform plumbing code and the nfpa national fire protection agency along with most if not all manufacturers of large gas appliances including water heaters and furnaces boilers and gas pool heaters and is listed in the installation procedures of the appliance manual installation instructions. Sediment traps are intentionally. The outlet of the meter is one such location.

It s called a sediment trap. The outlet of the meter is one such location. Drip legs are basically for catching condensate and moisture in a gas line. This pipe extension usually is at least 3 inches long and is intended to catch any water or foreign material that may be in the gas before the material gets into the appliance itself.

Hi fellow inspectors i was inspecting an hvac forced air furnace the other day and i saw this drip leg which does not cause the gas line to change a 90 degree direction which i mark this as defective. Sediment trap dirt pocket or drip leg at the appliance connection point there usually is a sediment trap or dirt pocket sometimes called a drip leg that includes a nipple and a cap. A sediment trap usually is installed as close to the appliance as possible. A drip leg can be installed anywhere at the low point in the piping system if there is moisture in the gas to allow for the removal of the condensation.

A drip leg can be installed anywhere at the low point in the piping system if there is moisture in the gas to allow for the removal of the condensation. The general rule of thumb is any appliance that will fire while unattended water heater furnace pool heater etc needs to have one installed.

Gasfurnace Sometimes Referred To As Forced Air Systems These Heating Systems Burn Natu Refrigeration And Air Conditioning Gas Furnace Heating And Plumbing

Gasfurnace Sometimes Referred To As Forced Air Systems These Heating Systems Burn Natu Refrigeration And Air Conditioning Gas Furnace Heating And Plumbing

Hvac Hacks Com Water Heater Hvac Hacks Water Heater Heater

Hvac Hacks Com Water Heater Hvac Hacks Water Heater Heater

York Gas Package Unit Hvac Hacks Com Hvac Hacks Hvac Humor Hvac

York Gas Package Unit Hvac Hacks Com Hvac Hacks Hvac Humor Hvac

Gas Line Connection Gas Water Heater Water Heater Heater

Gas Line Connection Gas Water Heater Water Heater Heater

Pin On Home Inspector

Pin On Home Inspector

Another Great Wow Moment Hvac Humor Hvac Hacks Hvac Filters

Another Great Wow Moment Hvac Humor Hvac Hacks Hvac Filters

Pin By Good Day Tools On Hvac Hacks Hacks Legs

Pin By Good Day Tools On Hvac Hacks Hacks Legs

Rheem Water Heater Hvac Hacks Plumbing Humor Hvac Humor

Rheem Water Heater Hvac Hacks Plumbing Humor Hvac Humor

Discount Plumbing Fixtures Plumbing Plumbing Fixtures Plumbing Problems

Discount Plumbing Fixtures Plumbing Plumbing Fixtures Plumbing Problems

Hvac Hacks Com Nice Platform Hvac Hacks Hvac Installation Hvac

Hvac Hacks Com Nice Platform Hvac Hacks Hvac Installation Hvac

Noise Complaint Hvac Hacks Com Hvac Hacks Hvac Humor Hvac Maintenance

Noise Complaint Hvac Hacks Com Hvac Hacks Hvac Humor Hvac Maintenance

Hack Work This Left Me Speechless Hvac Hacks Hvac Humor Refrigeration And Air Conditioning

Hack Work This Left Me Speechless Hvac Hacks Hvac Humor Refrigeration And Air Conditioning

Nine Section Steam Boiler Heatingseason Hvaclife Steam Boiler Hvac Gas Grill

Nine Section Steam Boiler Heatingseason Hvaclife Steam Boiler Hvac Gas Grill

Furnace Waste Oil Conversion By Gadget Homemade Furnace Waste Oil Conversion Constructed By Replacing The Propane B Waste Oil Burner Homemade Oil Diy Heater

Furnace Waste Oil Conversion By Gadget Homemade Furnace Waste Oil Conversion Constructed By Replacing The Propane B Waste Oil Burner Homemade Oil Diy Heater

Thanks Buddy Http Www Hvac Hacks Com Thanks Buddy Hvac Hacks Hvac Humor Hvac

Thanks Buddy Http Www Hvac Hacks Com Thanks Buddy Hvac Hacks Hvac Humor Hvac

Many Towns In Our Area Require That Any Furnace In The Attic Needs To Be In A Fire Rated Roof With A Sprinkler Head An Home Inspection Home Arlington Heights

Many Towns In Our Area Require That Any Furnace In The Attic Needs To Be In A Fire Rated Roof With A Sprinkler Head An Home Inspection Home Arlington Heights

Top Metalworking Album Resim

Top Metalworking Album Resim

Old Soul Hvac Hacks Hvac Old Soul

Old Soul Hvac Hacks Hvac Old Soul

3

3

Source : pinterest.com